Leak Location Correlators ::

Water Leak Detection

Leak Detection Van
Pre-Location Loggers
Acoustic Point Locators
Pinpointing With Gas
Leak Location Correlators
Flow Measurements
Correlux P-2

CorreluxP2.pngDigital correlator for leak location on water pipelines

The correlator Correlux P-2 is used for leak location on pipes for portable water. Water, escaping from a leak under pressure creates a noise which travels into both directions of the pipe. This noise is recorded by two sensors (piezo-microphones, hydrophones) attached to the pipe (e. g.: valves, hydrants), amplifi ed and transmitted to the correlator. The Correlux P-2 compares both signals (correlation) and calculates the exact distance to the leak by use of the signal delay, the sensor distance and the sound velocity.

Benefits

  • Easy to use
  • Optimised for plastic pipes
  • Long operating time
  • Sensor can be connected to the central unit
  • Sturdy housing

CorreluxP2_illustration.pngAll advantages at one glance

  • Easy handling with rotary encoder
  • Rugged and compact design
  • Simultaneous display of the correlation chart and the coherence spectrum (FFT- analysis)
  • Quick fi lter optimisation without using menus
  • Fast and easy leak identifi cation by using the overview measurement with unknown pipe parameters
  • High radio output for broad reach
  • Transmitter and correlator with direct headphones plug-in to listen live to the leak noise
  • Recharging the complete system in the closed case – direct charging is possible, too
  • Up to 6 pipe sections measurable
  • Active piezo ceramics accelerometers, best suited for plastic pipes
  • Automatic and manual fi lter adjustment 0 … 4000 Hz

Correlux-P2-kit_1.png

Correlux P-2

Processor

RISC processor for user interface

 

DSP processor for signal processing

Display

320 x 240 Pixel, 1/4-VGA monochrom

Data entry

Rotary coder with enter function

Mains

internal rechargeable battery NiMH; external 12 V DC (car adapter) or 230 V AC

Operation/charging time

>12h /<3h

Interface

RS232 (updates, data transmission, hard copy via PC software)

Connections

Sensor / Hydrophon direct connection, antenna, headphones/ charging, sliding contacts for charging in the case

Protection class

IP 67

Operation temperature

-20°C ... +60°C

Dimensions/Weight

270 x 130 x 240 mm; 3.3 kg

Transmitter TX A/TR X

Display

LCD, 2 x 16 characters

Read-out

Battery status, noise level, system status

Calliper

on/off/illumination, radio on/off, auto/man., Volume

Radio frequency

433 mHz

Transmitter power

<500 mW

Operation/charging time

>15h /<3h

Mains

internal rechargeable battery NiMH; external 12 V DC (car adapter) or 210 - 230 V AC

Interfaces

Sensor / Hydrophon direct connection, antenna, headphones/ charging

Protection class

IP 67 when in operation

Operation temperature

-20°C ... +50°C

Dimensions/weight

230 x 110 x 190 mm; 2.3 kg

Sensors PAM CORR

Sensors PAM CORR

Piezo sensor with active amplifier

Adapter

Magnet adapter

Operation temperature

-20°C ... +80°C

Dimensions/weight

90 x 78 mm; 0.4 kg

Scope of Delivery

Correlux P-2

P-2 Basic

P-2 Standard

P-2 Pro

Hardware

 

 

 

DK P2 correllator+A1

TX A transmitter +sensor

TX B transmitter +sensor

option

headphones

ground microphone

option

transport case

option

charger ( mains )

hydrophone

option

option

option

car adapter

option

option

option

       

Software

 

 

 

listening mode

 

option

trace memory

 

PC software

 

 

SebaKMT UK Limited, Unit C, Beversbrook Centre, Redman Road, Calne, Wiltshire, SN11 9PR, United Kingdom - Registered in England: 04593899

Copyright © 2012 SebaKMTUK. All Rights Reserved.

Website designed & maintained by Insight Global Limited

JoomlaWatch 1.2.12 - Joomla Monitor and Live Stats by Matej Koval